Define each measuring point
A pump skid may need separate suction and discharge readings. Mark both locations on the piping drawing and state whether the measurements support local indication, a PLC trend or pump control. Do not select both ranges from discharge pressure alone: the suction point may have a different pressure reference and operating envelope.
Build a realistic pressure envelope
Record normal pressure, start and stop conditions, the highest credible pressure and any vacuum condition. Ask the equipment designer about surge protection and the permitted overload at the instrument. A wider measuring range is not a substitute for checking pressure spikes and the mechanical rating of the connection.
Compare WESIVO candidates
The WESIVO 720 is a silicon piezoresistive pressure sensor with stainless-steel wetted parts. The WESIVO 728 adds local LCD indication in its industrial transmitter design. Review their individual documentation against the medium, connection, required output, ambient conditions and available installation space before choosing a configuration.
Prepare the inquiry and handover
Send a marked-up skid drawing, pressure values, water temperature, thread or flange standard, signal requirement and quantity per skid. At commissioning, compare the displayed engineering units and PLC scaling with the ordered range. Record an accessible reference reading and retain the instrument tag, order details and calibration document with the equipment file.
先定义每一个测点
泵组可能需要分别监测入口与出口压力。请在管路图上标记测点,说明用于就地显示、PLC 趋势记录还是泵组控制。入口的压力基准与工作范围可能不同,不宜仅依据出口压力统一选量程。
整理真实的压力边界
记录正常压力、启停工况、可能出现的最高压力与负压。向设备设计方确认防冲击措施及仪表允许过载。扩大测量范围不能代替对压力冲击和连接机械承压能力的核对。
比较 WESIVO 选型入口
WESIVO 720 为接液部件采用不锈钢的硅压阻压力传感器;WESIVO 728 工业压力变送器带 LCD 就地显示。请结合介质、连接、输出、环境与安装空间核对各自资料后确定配置。
准备询价和交付核对
询价时提供标注后的泵组图、压力值、水温、螺纹或法兰标准、信号要求及每套用量。调试时核对工程单位、PLC 换算范围与订购量程,并将参考读数、位号、订货配置及校准文件纳入设备档案。
Discuss your application
Send your medium, operating conditions, connection, output, quantity and destination. WESIVO will review the configuration before quotation.