工业过程测量仪表测量 / 校准 / 自动化
WESIVO 客户平台
WESIVO 应用选型方案

雨水回用储罐的无线液位监测方案

面向非饮用雨水回用储罐,规划液位测量、就地泵控和数据时效,并核对 WESIVO 4G 雷达型号的项目接入配置。

Application scope and evidence

Rainwater storage is a documented application for irrigation and other non-potable uses. EPA's 2013 rainwater-harvesting review also describes internet-connected systems that monitor cistern volume. This article is an application planning note based on that documented scenario, not a WESIVO customer case or a report of measured savings. The 仪表 and integration recommendations below are engineering considerations for a new project.

Define what the operator needs to know

For a facility with a rainwater tank serving irrigation or a utility water circuit, define three separate questions: how much usable water remains, whether a local pump may run, and whether the displayed reading is current. Record the lowest usable 液位, normal operating band and over流量 elevation on the tank drawing. A 液位 reading is not automatically a volume reading: volume requires the correct tank geometry or a verified 液位-to-volume table.

Review the radar measurement point

Provide tank height, roof and nozzle details, internal supports, inlet position and the highest expected water 液位. Ask the 仪表 supplier to review the measuring path, near-range limits and mounting arrangement for the selected configuration. Describe foam, condensation and turbulent filling rather than selecting an 仪表 from tank height alone. Keep the reference point consistent in the 仪表, local display and platform.

Separate monitoring from local control

Remote visibility can help an operator plan inspections and water use. A cloud display should not be the sole basis for preventing a pump from running dry or for handling over流量. Agree local control, over流量 routing and the response to a lost measurement with the equipment designer. Specify which alarm requires an on-site response and which simply asks an operator to investigate. These are project requirements, not confirmed functions of the products listed here.

Compare the WESIVO 4G candidates

The published WESIVO catalogue identifies WSRD-08WA and WSRD-08WB as 4G models in the 80 GHz radar 液位 family. They are candidates for configuration review, not an assurance that either model fits every rainwater tank. Confirm the measuring range, connection, supply and enclosure arrangement against the selected model documentation. Ask separately for the cellular configuration, actual telemetry sample and cloud protocol; a 4G label alone does not establish MQTT compatibility.

Commission the complete data path

Check the displayed 液位 at accessible known reference 液位s. Verify units, scaling and any volume conversion from the 仪表 to the receiving system. Disconnect the reporting path in a controlled commissioning test and confirm that old values are visibly marked as stale. Check how the system recovers when data returns. Retain the drawing, configuration, account-to-device mapping and acceptance results with the equipment file.

Prepare a useful RFQ

Send the tank drawing, medium, operating 液位 range, nozzle dimensions, supply, cellular deployment country, reporting interval, receiving platform, quantity and delivery destination. State whether the scope is monitoring only or includes separately specified local controls. WESIVO can review the proposed 仪表 configuration and identify the information needed to agree an integration plan.

应用范围与资料依据

雨水储存用于灌溉等非饮用回用场景,已有公开资料记录。美国 EPA 2013 年雨水收集研究也介绍了通过联网系统监测储水容积的做法。本文依据这一真实应用类型编写选型说明,不是 WESIVO 客户项目案例,也不报告未经核实的节水效果。下文仪表及接入建议属于新项目的工程核对事项。

明确运营人员需要知道什么

对于为灌溉或辅助用水回路供水的雨水储罐,应分别明确三件事:还剩多少可用水、就地水泵能否运行、平台显示值是否仍然有效。请在罐体图上标出最低可用液位、正常运行区间和溢流标高。液位读数不自动等于容积读数,容积换算需要正确的罐体几何信息或经核实的液位—容积表。

核对雷达测量位置

提供罐高、罐顶与短管尺寸、内部支撑、进水位置和最高预计水位,请供应商依据具体配置核对测量路径、近端限制及安装方式。说明泡沫、冷凝和进水扰动,不能只按罐高选仪表。仪表、就地显示与平台所采用的参考点应保持一致。

将远程监测与就地控制分开

远程查看有助于安排巡检和用水,但平台显示不应成为防止水泵空转或处理溢流的唯一依据。应与设备设计方明确就地控制、溢流路径和测量丢失时的处理方式,区分需要现场响应的报警与需要运营人员调查的提示。这些是项目要求,不代表本文列出的产品已具备相应控制功能。

比较 WESIVO 4G 选型入口

已发布的 WESIVO 样册将 WSRD-08WA、WSRD-08WB 列为 80 GHz 雷达液位系列的 4G 型号。它们可作为配置核对入口,不能据此认为任一型号适合所有雨水罐。请依据所选型号资料确认测量范围、连接、供电和外壳配置,并单独索取蜂窝通信配置、实际数据样例和平台协议;仅有 4G 标识不能确认 MQTT 兼容性。

调试完整数据链路

在可核对的已知液位检查显示值,验证仪表至接收系统的单位、比例换算及容积计算。在受控的调试条件下中断上报链路,检查旧数据是否明显标记为过期,再验证恢复通信后的处理方式。将图纸、配置、账号与设备归属关系以及验收结果一并纳入设备档案。

准备有效询价资料

请提供罐体图、介质、运行液位范围、短管尺寸、电源、蜂窝通信部署国家、上报周期、接收平台、数量和收货地区。说明需求仅为监测,还是另行包含就地控制。WESIVO 可据此核对仪表配置,并指出制定接入方案还需要的信息。

沟通您的应用需求

请提供介质、工况、连接、输出、数量及收货地区,WESIVO 将在报价前核对配置。

相关指南与产品分类

公开来源与产品资料